    NAME

    
    
    timeout
    
     
    untimeout
    
     
    callout_handle_init
    
     
    callout_init
    
     
    callout_init_mtx
    
     
    callout_stop
    
     
    callout_drain
    
     
    callout_reset
    
     
    callout_pending
    
     
    callout_active
    
     
    callout_deactivate
    
     - execute a function after a specified length of time
    
     
    

    SYNOPSIS

       #include <sys/types.h>
       #include <sys/systm.h>

    typedef void timeout_t (void *);
    
    struct callout_handle timeout (timeout_t *func void *arg int ticks);
    void callout_handle_init (struct callout_handle *handle);

    struct callout_handle handle = CALLOUT_HANDLE_INITIALIZER(&handle)
    
    void untimeout (timeout_t *func void *arg struct callout_handle handle);
    void callout_init (struct callout *c int mpsafe);
    void callout_init_mtx (struct callout *c struct mtx *mtx int flags);
    int callout_stop (struct callout *c);
    int callout_drain (struct callout *c);
    int callout_reset (struct callout *c int ticks timeout_t *func void *arg);
    int callout_pending (struct callout *c);
    int callout_active (struct callout *c);
    callout_deactivate (struct callout *c);
     

    DESCRIPTION

    The function timeout ();
    schedules a call to the function given by the argument Fa func to take place after Fa ticks Ns No /hz seconds. Non-positive values of Fa ticks are silently converted to the value `1' Fa func should be a pointer to a function that takes a Fa void * argument. Upon invocation, Fa func will receive Fa arg as its only argument. The return value from timeout ();
    is a struct callout_handle which can be used in conjunction with the untimeout ();
    function to request that a scheduled timeout be canceled. The timeout ();
    call is the old style and new code should use the callout_ (*);
    functions.

    The function callout_handle_init ();
    can be used to initialize a handle to a state which will cause any calls to untimeout ();
    with that handle to return with no side effects.

    Assigning a callout handle the value of CALLOUT_HANDLE_INITIALIZER ();
    performs the same function as callout_handle_init ();
    and is provided for use on statically declared or global callout handles.

    The function untimeout ();
    cancels the timeout associated with Fa handle using the Fa func and Fa arg arguments to validate the handle. If the handle does not correspond to a timeout with the function Fa func taking the argument Fa arg no action is taken. Fa handle must be initialized by a previous call to timeout (,);
    callout_handle_init (,);
    or assigned the value of CALLOUT_HANDLE_INITIALIZER (&handle);
    before being passed to untimeout (.);
    The behavior of calling untimeout ();
    with an uninitialized handle is undefined. The untimeout ();
    call is the old style and new code should use the callout_ (*);
    functions.

    As handles are recycled by the system, it is possible (although unlikely) that a handle from one invocation of timeout ();
    may match the handle of another invocation of timeout ();
    if both calls used the same function pointer and argument, and the first timeout is expired or canceled before the second call. The timeout facility offers O(1) running time for timeout ();
    and untimeout (.);
    Timeouts are executed from softclock ();
    with the Giant lock held. Thus they are protected from re-entrancy.

    The functions callout_init (,);
    callout_init_mtx (,);
    callout_stop (,);
    callout_drain ();
    and callout_reset ();
    are low-level routines for clients who wish to allocate their own callout structures.

    The function callout_init ();
    initializes a callout so it can be passed to callout_stop (,);
    callout_drain ();
    or callout_reset ();
    without any side effects. If the Fa mpsafe argument is zero, the callout structure is not considered to be ``multi-processor safe'' that is, the Giant lock will be acquired before calling the callout function, and released when the callout function returns.

    The callout_init_mtx ();
    function may be used as an alternative to callout_init (.);
    The parameter Fa mtx specifies a mutex that is to be acquired by the callout subsystem before calling the callout function, and released when the callout function returns. The following Fa flags may be specified:

    CALLOUT_RETURNUNLOCKED
    The callout function will release Fa mtx itself, so the callout subsystem should not attempt to unlock it after the callout function returns.

    The function callout_stop ();
    cancels a callout if it is currently pending. If the callout is pending, then callout_stop ();
    will return a non-zero value. If the callout is not set, has already been serviced or is currently being serviced, then zero will be returned. If the callout has an associated mutex, then that mutex must be held when this function is called.

    The function callout_drain ();
    is identical to callout_stop ();
    except that it will wait for the callout to be completed if it is already in progress. This function MUST NOT be called while holding any locks on which the callout might block, or deadlock will result. Note that if the callout subsystem has already begun processing this callout, then the callout function may be invoked during the execution of callout_drain (.);
    However, the callout subsystem does guarantee that the callout will be fully stopped before callout_drain ();
    returns.

    The function callout_reset ();
    first performs the equivalent of callout_stop ();
    to disestablish the callout, and then establishes a new callout in the same manner as timeout (.);
    If there was already a pending callout and it was rescheduled, then callout_reset ();
    will return a non-zero value. If the callout has an associated mutex, then that mutex must be held when this function is called.

    The macros callout_pending (,);
    callout_active ();
    and callout_deactivate ();
    provide access to the current state of the callout. Careful use of these macros can avoid many of the race conditions that are inherent in asynchronous timer facilities; see Sx Avoiding Race Conditions below for further details. The callout_pending ();
    macro checks whether a callout is pending a callout is considered pending when a timeout has been set but the time has not yet arrived. Note that once the timeout time arrives and the callout subsystem starts to process this callout, callout_pending ();
    will return FALSE even though the callout function may not have finished (or even begun) executing. The callout_active ();
    macro checks whether a callout is marked as active and the callout_deactivate ();
    macro clears the callout's active flag. The callout subsystem marks a callout as active when a timeout is set and it clears the active flag in callout_stop ();
    and callout_drain (,);
    but it does not clear it when a callout expires normally via the execution of the callout function.  

    Avoiding Race Conditions

    The callout subsystem invokes callout functions from its own timer context. Without some kind of synchronization it is possible that a callout function will be invoked concurrently with an attempt to stop or reset the callout by another thread. In particular, since callout functions typically acquire a mutex as their first action, the callout function may have already been invoked, but be blocked waiting for that mutex at the time that another thread tries to reset or stop the callout.

    The callout subsystem provides a number of mechanisms to address these synchronization concerns:

    1. If the callout has an associated mutex that was specified using the callout_init_mtx ();
      function (or implicitly specified as the Giant mutex using callout_init ();
      with Fa mpsafe set to FALSE ) then this mutex is used to avoid the race conditions. The associated mutex must be acquired by the caller before calling callout_stop ();
      or callout_reset ();
      and it is guaranteed that the callout will be correctly stopped or reset as expected. Note that it is still necessary to use callout_drain ();
      before destroying the callout or its associated mutex.
    2. The return value from callout_stop ();
      and callout_reset ();
      indicates whether or not the callout was removed. If it is known that the callout was set and the callout function has not yet executed, then a return value of FALSE indicates that the callout function is about to be called. For example:
      if (sc->sc_flags & SCFLG_CALLOUT_RUNNING) {
              if (callout_stop(&sc->sc_callout)) {
                      sc->sc_flags &= ~SCFLG_CALLOUT_RUNNING;
                      /* successfully stopped */
              } else {
                      /*
                       * callout has expired and callout
                       * function is about to be executed
                       */
              }
      }
      
    3. The callout_pending (,);
      callout_active ();
      and callout_deactivate ();
      macros can be used together to work around the race conditions. When a callout's timeout is set, the callout subsystem marks the callout as both active and pending When the timeout time arrives, the callout subsystem begins processing the callout by first clearing the pending flag. It then invokes the callout function without changing the active flag, and does not clear the active flag even after the callout function returns. The mechanism described here requires the callout function itself to clear the active flag using the callout_deactivate ();
      macro. The callout_stop ();
      and callout_drain ();
      functions always clear both the active and pending flags before returning.

      The callout function should first check the pending flag and return without action if callout_pending ();
      returns TRUE This indicates that the callout was rescheduled using callout_reset ();
      just before the callout function was invoked. If callout_active ();
      returns FALSE then the callout function should also return without action. This indicates that the callout has been stopped. Finally, the callout function should call callout_deactivate ();
      to clear the active flag. For example:

      mtx_lock(&sc->sc_mtx);
      if (callout_pending(&sc->sc_callout)) {
              /* callout was reset */
              mtx_unlock(&sc->sc_mtx);
              return;
      }
      if (!callout_active(&sc->sc_callout)) {
              /* callout was stopped */
              mtx_unlock(&sc->sc_mtx);
              return;
      }
      callout_deactivate(&sc->sc_callout);
      /* rest of callout function */
      

      Together with appropriate synchronization, such as the mutex used above, this approach permits the callout_stop ();
      and callout_reset ();
      functions to be used at any time without races. For example:

      mtx_lock(&sc->sc_mtx);
      callout_stop(&sc->sc_callout);
      /* The callout is effectively stopped now. */
      

      If the callout is still pending then these functions operate normally, but if processing of the callout has already begun then the tests in the callout function cause it to return without further action. Synchronization between the callout function and other code ensures that stopping or resetting the callout will never be attempted while the callout function is past the callout_deactivate ();
      call.

      The above technique additionally ensures that the active flag always reflects whether the callout is effectively enabled or disabled. If callout_active ();
      returns false, then the callout is effectively disabled, since even if the callout subsystem is actually just about to invoke the callout function, the callout function will return without action.

    There is one final race condition that must be considered when a callout is being stopped for the last time. In this case it may not be safe to let the callout function itself detect that the callout was stopped, since it may need to access data objects that have already been destroyed or recycled. To ensure that the callout is completely finished, a call to callout_drain ();
    should be used.  

    RETURN VALUES

    The timeout ();
    function returns a struct callout_handle that can be passed to untimeout (.);
    The callout_stop ();
    and callout_drain ();
    functions return non-zero if the callout was still pending when it was called or zero otherwise.  

    HISTORY

    The current timeout and untimeout routines are based on the work of An Adam M. Costello and An George Varghese , published in a technical report entitled "Redesigning the BSD Callout and Timer Facilities" and modified slightly for inclusion in Fx by An Justin T. Gibbs . The original work on the data structures used in this implementation was published by An G. Varghese and An A. Lauck in the paper "Hashed and Hierarchical Timing Wheels: Data Structures for the Efficient Implementation of a Timer Facility" in the "Proceedings of the 11th ACM Annual Symposium on Operating Systems Principles" . The current implementation replaces the long standing BSD linked list callout mechanism which offered O(n) insertion and removal running time but did not generate or require handles for untimeout operations.


     