    NAME
         dr_daemon - Enterprise 10000 Dynamic Reconfiguration daemon
    
    SYNOPSIS
         dr_daemon [ -a ]
    
    DESCRIPTION
         The dr_daemon is a Remote Procedure Call (RPC) program  that
         provides  the  interface to the Sun Enterprise 10000 Dynamic
         Reconfiguration (DR) driver, dr(7).  See dr(7D).  The  Host-
         view  and  DR applications provide the user interface to DR.
         See hostview(1M) in the Sun Enterprise 10000 SSP 3.2  Refer-
         ence  Manual  and dr(1M) in the Sun Enterprise 10000 Dynamic
         Reconfiguration Reference Manual.
    
    OPTIONS
         The following options are supported:
    
         -a    Disable communications with the Alternate Pathing (AP)
               daemon. See ap_daemon(1M) in the Sun Enterprise Server
               Alternate Pathing Reference Manual.
    
    CONFIGURATION INFORMATION
          The /platform/SUNW,Ultra-Enterprise-10000/lib/dr_daemon RPC
         program  name  is  DRPROG, its RPC program number is 300326,
         and its underlying protocol is TCP. It  is   invoked  as  an
         inetd  server using the TCP transport.  The UID required for
         access to the daemon is ssp. This UID  can  be  a  non-login
         UID.  The  entry  for the daemon in the /etc/inetd.conf file
         is:
    
         300326/4 tli rpc/tcp wait root \
              /platform/SUNW,Ultra-Enterprise-10000/lib/dr_daemon
          The daemon's only clients are  Hostview  and  DR.  Hostview
         provides a GUI interface; dr(1M) is a command-line interface
         for non-windowing environments.  The  DR  daemon  uses  sys-
         log(3) to report status and error messages. These error mes-
         sages are  logged  with  the  LOG_DAEMON  facility  and  the
         LOG_ERR and LOG_NOTICE priorities. dr_daemon communicates by
         way of RPC with the Alternate Pathing (AP) daemon to  notify
         the  AP  software  when  controllers  are  attached  to  and
         detached from the system, or to gather information about the
         system  configuration.  See  ap_daemon(1M) in the Sun Enter-
         prise Server Alternate Pathing Reference Manual
    
    ATTRIBUTES
         See attributes(5) for descriptions of the  following  attri-
         butes:
    
    
    
         ____________________________________________________
        | ATTRIBUTE TYPE        | ATTRIBUTE VALUE           |
        |_______________________|___________________________|
        | Availability          | SUNWdrr.u                 |
        |_______________________|___________________________|
    
    
    SEE ALSO
         add_drv(1M),   drv_config(1M),   devlinks(1M),    disks(1M),
         inetd(1M),  ports(1M),  tapes(1M),  prtconf(1M),  syslog(3),
         attributes(5), dr(7D)
    
         dr(1M) in the Sun Enterprise 10000  Dynamic  Reconfiguration
         Reference Manual
    
         hostview(1M) and hpost(1M) in the Sun Enterprise  10000  SSP
         3.2 Reference Manual
    
         ap(1M) and ap_daemon(1M) in the Sun Enterprise Server Alter-
         nate Pathing Reference Manual
    
         Sun Enterprise Server Alternate Pathing 2.3 User Guide
    
    
    
    